Products
HCSSJ
cold-shrink
joint
hydrophobicity
Applying to cold area, humid area, salt mist area and seriously polluted area. Special outer sheaths are available on request, such as heat shrink tubing, cast resin, armoring tape, etc.
留言
- Basic Information
- Technical Parameter
- Ordering Data
-
Shelf life & storage:
HCSSJ Cold Shrink Joint has long shelf life when stored in a humidity controlled storage(-10℃ to 40℃ and < 75% relative humidity).
Features:
Safety
Without using torches or any auxiliary tools.Stability
Cold-shrink joint is designed with geometric stress cone on both sides and Faraday Cage in the middle so that stress cone and insulator always keep the active pressure and steady long-term operation to cable.Easy installation
Pull out the plastic string from silicon rubber parts, the silicon rubber will tightly shrink on the need position, which will reduce installation defects.Material performance(LSR)
Excellent performance in anti-flouring, ageing resistance, hydrophobicity, hydrophobicity transference and cold resistance.Wide usage
Applying to cold area, humid area, salt mist area and seriously polluted area. Special outer sheaths are available on request, such as heat shrink tubing, cast resin, armoring tape, etc.Small size
Smallish cold-shrink joint can minimize stripping distance effectively.
-
Key technical performances:
Standard
IEC 60502
Voltage classes
6/10(12)kV
8.7/15(17.5)kV
12/20(24)kV
18/30(36)kV
26/35(40.5)kV
Partial discharge test at ambient temperature
10kV, <10pC
15kV, <10pC
20kV, <10pC
30kV, <10pC
45kV,<10pC
AC withstand voltage test
27kV 5min
39kV 5min
54kV 5min
81kV 5min
117kV 5min
Impulse voltage withstand
±75kV each polarity 10 times
±95kV each polarity 10 times
±125kV each polarity 10 times
±170kV each polarity 10 times
±200kV each polarity 10 times
-
Selection table:
6/10(12)kV
Joint
Cable Insulation OD(mm)
Cable Conductor Cross-section(mm²)
1x1 core
HCSSJ-12-7095-1
16.5mm—19.7mm
70mm²--95mm²
HCSSJ-12-1215-1
19.7mm—23.5mm
120mm²--150mm²
HCSSJ-12-1830-1
22.5mm—31.3mm
185mm²--300mm²
HCSSJ-12-4063-1
28.9mm—38.0mm
400mm²--630mm²
1x3 cores
HCSSJ-12-7095
16.5mm—19.7mm
70mm²--95mm²
HCSSJ-12-1215
19.7mm—23.5mm
120mm²--150mm²
HCSSJ-12-1830
22.5mm—31.3mm
185mm²--300mm²
HCSSJ-12-4063
28.9mm—38.0mm
400mm²--630mm²
8.7/15(17.5)kV
Joint
Cable Insulation OD(mm)
Cable Conductor Cross-section(mm²)
1x1 core
HCSSJ-17.5-2550-1
16.5mm—19.7mm
25mm²--50mm²
HCSSJ-17.5-7012-1
19.7mm—23.5mm
70mm²--120mm²
HCSSJ-17.5-1530-1
22.5mm—31.3mm
150mm²--300mm²
HCSSJ-17.5-4050-1
28.9mm—38.0mm
400mm²--500mm²
HCSSJ-17.5-630-1
38.0m m—44.1mm
630mm²
1x3 cores
HCSSJ-17.5-2550
16.5mm—19.7mm
25mm²--50mm²
HCSSJ-17.5-7012
19.7mm—23.5mm
70mm²--120mm²
HCSSJ-17.5-1530
22.5mm—31.3mm
150mm²--300mm²
HCSSJ-17.5-4050
28.9mm—38.0mm
400mm²--500mm²
HCSSJ-17.5-630
38.0mm—44.1mm
630mm²
12/20(24)kV
Indoor Termination
Outdoor Termination
Cable Insulation OD(mm)
Cable Conductor Cross-section(mm²)
1x1 core
HCSIT-24-3550-1
HCSOT-24-3550-1
19.7mm—23.5mm
35mm²--50mm²
HCSIT-24-7015-1
HCSOT-24-7015-1
22.5mm—31.3mm
70mm²--150mm²
HCSIT-24-1840-1
HCSOT-24-1840-1
28.9mm—38.0mm
185mm²--400mm²
HCSIT-24-5063-1
HCSOT-24-5063-1
38.0mm—44.1mm
500mm²--630mm²
1x3 cores
HCSIT-24-3550
HCSOT-24-3550
19.7mm—23.5mm
35mm²--50mm²
HCSIT-24-7015
HCSOT-24-7015
22.5mm—31.3mm
70mm²--150mm²
HCSIT-24-1840
HCSOT-24-1840
28.9mm—38.0mm
185mm²--400mm²
HCSIT-24-5063
HCSOT-24-5063
38.0mm—44.1mm
500mm²--630mm²
18/30(36)kV
Joint
Cable Insulation OD(mm)
Cable Conductor Cross-section(mm²)
1x1 core
HCSSJ-36-5015-1
25.9mm—33.9mm
50mm²--150mm²
HCSSJ-36-1830-1
33.7mm—41.3mm
185mm²--300mm²
HCSSJ-36-4050-1
41.3mm—47.0mm
400mm²--500mm²
HCSSJ-36-630-1
47.0mm—53.5mm
630mm²
1x3 cores
HCSSJ-36-5015
25.9mm—33.9mm
50mm²--150mm²
HCSSJ-36-1830
33.7mm—41.3mm
185mm²--300mm²
HCSSJ-36-4050
41.3mm—47.0mm
400mm²--500mm²
HCSSJ-36-630
47.0mm—53.5mm
630mm²
26/35(40.5)kV
Joint
Cable Insulation OD(mm)
Cable Conductor Cross-section(mm²)
1x1 core
HCSSJ-40.5-5015-1
33.7mm—41.6mm
50mm²--150mm²
HCSSJ-40.5-1830-1
41.3mm—47.0mm
185mm²--300mm²
HCSSJ-40.5-4063-1
47.0mm—53.5mm
400mm²--630mm²
1x3 cores
HCSSJ-40.5-5015
33.7mm—41.6mm
50mm²--150mm²
HCSSJ-40.5-1830
41.3mm—47.0mm
185mm²--300mm²
HCSSJ-40.5-4063
47.0mm—53.5mm
400mm²--630mm²
*NOTE:
1. Cable insulation outer diameter is one of the prerequisite for cable accessories selection.
2. Above product selection is according to the IEC standard cable.
3. Above product outer sheath is complete with heat shrinkable tubing.
Related products