For XLPE or EPR insulated, 1 or 3 cores cables up to 36kV
keyword:

Heat Shrink Joint

Applications:

Passed type test according to CENELEC HD 629.1 S2 & IEC 60502 in KEMA

Detailed Specification Download:

留言
  • Basic Information
  • Technical Parameter
  • Ordering Data
    • Commodity name: HKSJ
    • Applications: Passed type test according to CENELEC HD 629.1 S2 & IEC 60502 in KEMA

    For XLPE or EPR insulated, 1 or 3 cores cables up to 36kV

    Shelf life & storage:

    HKSJ Heat Shrink Joint has long shelf life when stored in a humidity controlled storage(-10℃ to 40℃ and < 75% relative humidity).

     

    Features:

    High mechanical strength

    Wide cross section range suitable for all types of connectors 

    Compact dimensions 

    Weathering stability 

    Allows immediate reenergizing

    Passed type test according to CENELEC HD 629.1 S2 & IEC 60502 in KEMA.

     

  • Key technical performances:

     

    Standard

    IEC 60502

    Voltage classes

    6/10(12)kV

    8.7/15(17.5)kV

    12/20(24)kV

    18/30(36)kV

    Partial discharge test at ambient temperature 

    10kV, <10pC

    15kV, <10pC

    20kV, <10pC

    30kV, <10pC

    AC withstand voltage test 

    27kV 5min

    39kV 5min

    54kV 5min

    81kV 5min

    Impulse voltage withstand

    ±75kV each polarity 10 times

    ±95kV each polarity 10 times

    ±125kV each polarity 10 times

    ±170kV each polarity 10 times

  • Selection table:

     

    6.35/11(12)kV

     

    Joint

    Cable Insulation OD(mm)

    Cable Conductor Cross-section(mm²)

    1x1 core 

    HKSJ-12/1×25-50

    12.0mm-16.0mm

    25mm²--50mm²

    HKSJ-12/1×70-150

    17.6mm-22.8mm

    70-mm²--150mm²

    HKSJ-12/1×185-300

    24.0mm-31.0mm

    185mm²--300mm²

    HKSJ-12/1×400-500

    31.5mm-37.0mm

    400mm²--500mm²

    HKSJ-12/1×630

    38.0mm-41.9mm

    630mm²

    1x3 cores 

    HKSJ-12/3×25-50

    12.0mm-16.0mm

    25mm²--50mm²

    HKSJ-12/3×70-150

    17.6mm-22.8mm

    70-mm²--150mm²

    HKSJ-12/3×185-300

    24.0mm-31.0mm

    185mm²--300mm²

    HKSJ-12/3×400-500

    31.5mm-37.0mm

    400mm²--500mm²

     

    8.7/15(17.5)kV

     

    Joint

    Cable Insulation OD(mm)

    Cable Conductor Cross-section(mm²)

    1x1 core 

    HKSJ-17.5/1×25-50

    16.0mm-19.5mm

    25mm²--50mm²

    HKSJ-17.5/1×70-150

    20.3mm-23.5mm

    70-mm²--150mm²

    HKSJ-17.5/1×185-300

    24.0mm-31.0mm

    185mm²--300mm²

    HKSJ-17.5/1×400-500

    31.5mm-37.0mm

    400mm²--500mm²

    HKSJ-17.5/1×630

    38.0mm-41.9mm

    630mm²

    1x3 cores 

    HKSJ-17.5/3×25-50

    16.0mm-19.5mm

    25mm²--50mm²

    HKSJ-17.5/3×70-150

    20.3mm-23.5mm

    70-mm²--150mm²

    HKSJ-17.5/3×185-300

    24.0mm-31.0mm

    185mm²--300mm²

    HKSJ-17.5/3×400-500

    31.5mm-37.0mm

    400mm²--500mm²

     

    12/20(24)kV

     

    Joint

    Cable Insulation OD(mm)

    Cable Conductor Cross-section(mm²)

    1x1 core 

    HKSJ-24/1×25-50

    17.5mm-20.3mm

    25mm²--50mm²

    HKSJ-24/1×70-150

    21.5mm-26.5mm

    70-mm²--150mm²

    HKSJ-24/1×185-300

    27.5mm-33.0mm

    185mm²--300mm²

    HKSJ-24/1×400-500

    34.2mm-39.5mm

    400mm²--500mm²

    HKSJ-24/1×630

    40.5mm-43.0mm

    630mm²

    1x3 cores 

    HKSJ-24/3×25-50

    17.5mm-20.3mm

    25mm²--50mm²

    HKSJ-24/3×70-150

    21.5mm-26.5mm

    70-mm²--150mm²

    HKSJ-24/3×185-300

    27.5mm-32.8mm

    185mm²--300mm²

    HKSJ-24/3×400-500

    33.5mm-39.5mm

    400mm²--500mm²

     

    18/30(36)kV

     

    Joint

    Cable Insulation OD(mm)

    Cable Conductor Cross-section(mm²)

    1x1 core 

    HKSJ-36/1×50-95

    25.0mm-29.5mm

    50mm²--95mm²

    HKSJ-36/1×120-240

    30.5mm—36.5mm

    120mm²--240mm²

    HKSJ-36/1×300-400

    38.0mm-42.5mm

    300mm2-400mm²

    HKSJ-36/1×500-630

    43.5mm-48.5mm

    500mm2--630mm²

    1x3 cores

    HKSJ-36/3×50-95

    25.0mm-29.5mm

    50mm²--95mm²

    HKSJ-36/3×120-240

    30.5mm—36.5mm

    120mm²--240mm²

    HKSJ-36/3×300-400

    38.0mm-42.5mm

    300mm2--400mm²

     

    *NOTE:

    1. Cable insulation outer diameter is one of the prerequisite for cable accessories selection.

    2. Above product selection is according to the IEC standard cable.

     